Over 20 years of experience in power sector! Technical expertise & refurbishing offered to hundreds of large power transformers and primary equipment of 110-750 kV! NOVA INDUSTRIAL S.A. was the official consultant of CNTEE Transelectrica, for the period 2015-2018, in the field of “Power Stations”, for the second consecutive time after the period 2011 – 2014! Our know-how, for your safety !

NOVA TRAFOMON 5M

The NOVA TRAFOMON 5M equipment is intended for on-line monitoring of medium power transformers and shunt reactors, providing online information on:

  • Operating status: the transformer complies / does not correspond to the operating regulations, it is connected / disconnected to / from the network;
  • Operating conditions: currents, overloads, voltages, voltage increases, frequency, power factor, powers (active, reactive, apparent), temperatures (winding temperature, oil temperature, temperature at the hottest point), etc .;
  • Operating status of the active part (core + windings + connections to isolated passages + internal earthing connections) by online monitoring of:
    • Concentrations of gases dissolved in oil: hydrogen (H2), acetylene (C2H2) – optional, carbon monoxide (CO) – optional, methane (CH4) – optional;
    • Partial discharges: acoustic signals produced by partial discharges – optional; or acoustic signals and electrical signals produced by partial discharges – optional;
  • Degree of wetting of the insulation by: on-line measurement of the water content in the oil and determination of the water content in the solid insulation;
  • Cooling system operating status:
    • Number of coolers (cooling batteries) in operation;
    • Highlighting the oil pumps and fans in operation, evaluating the cooling efficiency of the coolers, establishing the total operating time or the time between overhauls / repairs for the oil pumps and / or electro-fans;
    • Displaying the appropriate / unsuitable condition for the cooling system;
  • The state of the insulation of the insulated high voltage passages provided with the socket for measuring the tangent of the dielectric loss angle, by:
    • Measuring the current through the C1 dielectric, determining the imbalance current resulting from the phasor summation of the currents through the C1 dielectric of the isolated passages mounted on the R, S, T phases of the same three-phase winding;
    • Measuring the capacity of the C1 dielectric at each of the isolated high voltage passages, measuring the tangent of the dielectric loss angle between currents through two isolated passages from the phases of the same winding;
    • Displaying the appropriate / unsuitable condition for high voltage isolated crossings;
  • Operating status of the control switch under load by: monitoring the operating position of the switch; measuring the current through the electric drive motor and its imprint; counting the number of employees; measuring the temperature difference between the oil temperature in the breaker tank and the oil temperature in the transformer tank (optional); vibration measurement during operation (optional); monitoring the contact states for: plot switching commands, signaling the minimum plot stroke limit and the maximum plot respectively; displaying the corresponding / unsuitable status for the on-load tap-changer;
  • The condition of the oil conservator afferent to the main tank: the oil level in the conservator, signaling when reaching the maximum and minimum level, respectively;
  • Condition of the conservator related to the control switch under load: signaling when reaching the maximum and minimum level, respectively;
  • Operating status of the Buchholz relay: signaling stage and trigger stage, respectively;
  • The operating state of the overpressure relay corresponding to the plot switch breaker tank.

NOVA TRAFOMON 5M can be used independently or in an integrated on-line monitoring system of primary equipment in high voltage power stations – Smart Grids.

NOVA TRAFOMON 5M